Interface Eac3Settings.Builder

All Superinterfaces:
Buildable, CopyableBuilder<Eac3Settings.Builder,Eac3Settings>, SdkBuilder<Eac3Settings.Builder,Eac3Settings>, SdkPojo
Enclosing class:
Eac3Settings

public static interface Eac3Settings.Builder extends SdkPojo, CopyableBuilder<Eac3Settings.Builder,Eac3Settings>
  • Method Details

    • attenuationControl

      Eac3Settings.Builder attenuationControl(String attenuationControl)
      If set to ATTENUATE_3_DB, applies a 3 dB attenuation to the surround channels. Only used for 3/2 coding mode.
      Parameters:
      attenuationControl - If set to ATTENUATE_3_DB, applies a 3 dB attenuation to the surround channels. Only used for 3/2 coding mode.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • attenuationControl

      Eac3Settings.Builder attenuationControl(Eac3AttenuationControl attenuationControl)
      If set to ATTENUATE_3_DB, applies a 3 dB attenuation to the surround channels. Only used for 3/2 coding mode.
      Parameters:
      attenuationControl - If set to ATTENUATE_3_DB, applies a 3 dB attenuation to the surround channels. Only used for 3/2 coding mode.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • bitrate

      Eac3Settings.Builder bitrate(Integer bitrate)
      Specify the average bitrate in bits per second. The bitrate that you specify must be a multiple of 8000 within the allowed minimum and maximum values. Leave blank to use the default bitrate for the coding mode you select according ETSI TS 102 366. Valid bitrates for coding mode 1/0: Default: 96000. Minimum: 32000. Maximum: 3024000. Valid bitrates for coding mode 2/0: Default: 192000. Minimum: 96000. Maximum: 3024000. Valid bitrates for coding mode 3/2: Default: 384000. Minimum: 192000. Maximum: 3024000.
      Parameters:
      bitrate - Specify the average bitrate in bits per second. The bitrate that you specify must be a multiple of 8000 within the allowed minimum and maximum values. Leave blank to use the default bitrate for the coding mode you select according ETSI TS 102 366. Valid bitrates for coding mode 1/0: Default: 96000. Minimum: 32000. Maximum: 3024000. Valid bitrates for coding mode 2/0: Default: 192000. Minimum: 96000. Maximum: 3024000. Valid bitrates for coding mode 3/2: Default: 384000. Minimum: 192000. Maximum: 3024000.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
    • bitstreamMode

      Eac3Settings.Builder bitstreamMode(String bitstreamMode)
      Specify the bitstream mode for the E-AC-3 stream that the encoder emits. For more information about the EAC3 bitstream mode, see ATSC A/52-2012 (Annex E).
      Parameters:
      bitstreamMode - Specify the bitstream mode for the E-AC-3 stream that the encoder emits. For more information about the EAC3 bitstream mode, see ATSC A/52-2012 (Annex E).
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • bitstreamMode

      Eac3Settings.Builder bitstreamMode(Eac3BitstreamMode bitstreamMode)
      Specify the bitstream mode for the E-AC-3 stream that the encoder emits. For more information about the EAC3 bitstream mode, see ATSC A/52-2012 (Annex E).
      Parameters:
      bitstreamMode - Specify the bitstream mode for the E-AC-3 stream that the encoder emits. For more information about the EAC3 bitstream mode, see ATSC A/52-2012 (Annex E).
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • codingMode

      Eac3Settings.Builder codingMode(String codingMode)
      Dolby Digital Plus coding mode. Determines number of channels.
      Parameters:
      codingMode - Dolby Digital Plus coding mode. Determines number of channels.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • codingMode

      Eac3Settings.Builder codingMode(Eac3CodingMode codingMode)
      Dolby Digital Plus coding mode. Determines number of channels.
      Parameters:
      codingMode - Dolby Digital Plus coding mode. Determines number of channels.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • dcFilter

      Eac3Settings.Builder dcFilter(String dcFilter)
      Activates a DC highpass filter for all input channels.
      Parameters:
      dcFilter - Activates a DC highpass filter for all input channels.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • dcFilter

      Eac3Settings.Builder dcFilter(Eac3DcFilter dcFilter)
      Activates a DC highpass filter for all input channels.
      Parameters:
      dcFilter - Activates a DC highpass filter for all input channels.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • dialnorm

      Eac3Settings.Builder dialnorm(Integer dialnorm)
      Sets the dialnorm for the output. If blank and input audio is Dolby Digital Plus, dialnorm will be passed through.
      Parameters:
      dialnorm - Sets the dialnorm for the output. If blank and input audio is Dolby Digital Plus, dialnorm will be passed through.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
    • dynamicRangeCompressionLine

      Eac3Settings.Builder dynamicRangeCompressionLine(String dynamicRangeCompressionLine)
      Choose the Dolby Digital dynamic range control (DRC) profile that MediaConvert uses when encoding the metadata in the Dolby Digital stream for the line operating mode. Related setting: When you use this setting, MediaConvert ignores any value you provide for Dynamic range compression profile. For information about the Dolby Digital DRC operating modes and profiles, see the Dynamic Range Control chapter of the Dolby Metadata Guide at https://developer.dolby.com/globalassets/professional/documents/dolby-metadata-guide.pdf.
      Parameters:
      dynamicRangeCompressionLine - Choose the Dolby Digital dynamic range control (DRC) profile that MediaConvert uses when encoding the metadata in the Dolby Digital stream for the line operating mode. Related setting: When you use this setting, MediaConvert ignores any value you provide for Dynamic range compression profile. For information about the Dolby Digital DRC operating modes and profiles, see the Dynamic Range Control chapter of the Dolby Metadata Guide at https://developer.dolby.com/globalassets/professional/documents/dolby-metadata-guide.pdf.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • dynamicRangeCompressionLine

      Eac3Settings.Builder dynamicRangeCompressionLine(Eac3DynamicRangeCompressionLine dynamicRangeCompressionLine)
      Choose the Dolby Digital dynamic range control (DRC) profile that MediaConvert uses when encoding the metadata in the Dolby Digital stream for the line operating mode. Related setting: When you use this setting, MediaConvert ignores any value you provide for Dynamic range compression profile. For information about the Dolby Digital DRC operating modes and profiles, see the Dynamic Range Control chapter of the Dolby Metadata Guide at https://developer.dolby.com/globalassets/professional/documents/dolby-metadata-guide.pdf.
      Parameters:
      dynamicRangeCompressionLine - Choose the Dolby Digital dynamic range control (DRC) profile that MediaConvert uses when encoding the metadata in the Dolby Digital stream for the line operating mode. Related setting: When you use this setting, MediaConvert ignores any value you provide for Dynamic range compression profile. For information about the Dolby Digital DRC operating modes and profiles, see the Dynamic Range Control chapter of the Dolby Metadata Guide at https://developer.dolby.com/globalassets/professional/documents/dolby-metadata-guide.pdf.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • dynamicRangeCompressionRf

      Eac3Settings.Builder dynamicRangeCompressionRf(String dynamicRangeCompressionRf)
      Choose the Dolby Digital dynamic range control (DRC) profile that MediaConvert uses when encoding the metadata in the Dolby Digital stream for the RF operating mode. Related setting: When you use this setting, MediaConvert ignores any value you provide for Dynamic range compression profile. For information about the Dolby Digital DRC operating modes and profiles, see the Dynamic Range Control chapter of the Dolby Metadata Guide at https://developer.dolby.com/globalassets/professional/documents/dolby-metadata-guide.pdf.
      Parameters:
      dynamicRangeCompressionRf - Choose the Dolby Digital dynamic range control (DRC) profile that MediaConvert uses when encoding the metadata in the Dolby Digital stream for the RF operating mode. Related setting: When you use this setting, MediaConvert ignores any value you provide for Dynamic range compression profile. For information about the Dolby Digital DRC operating modes and profiles, see the Dynamic Range Control chapter of the Dolby Metadata Guide at https://developer.dolby.com/globalassets/professional/documents/dolby-metadata-guide.pdf.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • dynamicRangeCompressionRf

      Eac3Settings.Builder dynamicRangeCompressionRf(Eac3DynamicRangeCompressionRf dynamicRangeCompressionRf)
      Choose the Dolby Digital dynamic range control (DRC) profile that MediaConvert uses when encoding the metadata in the Dolby Digital stream for the RF operating mode. Related setting: When you use this setting, MediaConvert ignores any value you provide for Dynamic range compression profile. For information about the Dolby Digital DRC operating modes and profiles, see the Dynamic Range Control chapter of the Dolby Metadata Guide at https://developer.dolby.com/globalassets/professional/documents/dolby-metadata-guide.pdf.
      Parameters:
      dynamicRangeCompressionRf - Choose the Dolby Digital dynamic range control (DRC) profile that MediaConvert uses when encoding the metadata in the Dolby Digital stream for the RF operating mode. Related setting: When you use this setting, MediaConvert ignores any value you provide for Dynamic range compression profile. For information about the Dolby Digital DRC operating modes and profiles, see the Dynamic Range Control chapter of the Dolby Metadata Guide at https://developer.dolby.com/globalassets/professional/documents/dolby-metadata-guide.pdf.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • lfeControl

      Eac3Settings.Builder lfeControl(String lfeControl)
      When encoding 3/2 audio, controls whether the LFE channel is enabled
      Parameters:
      lfeControl - When encoding 3/2 audio, controls whether the LFE channel is enabled
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • lfeControl

      Eac3Settings.Builder lfeControl(Eac3LfeControl lfeControl)
      When encoding 3/2 audio, controls whether the LFE channel is enabled
      Parameters:
      lfeControl - When encoding 3/2 audio, controls whether the LFE channel is enabled
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • lfeFilter

      Eac3Settings.Builder lfeFilter(String lfeFilter)
      Applies a 120Hz lowpass filter to the LFE channel prior to encoding. Only valid with 3_2_LFE coding mode.
      Parameters:
      lfeFilter - Applies a 120Hz lowpass filter to the LFE channel prior to encoding. Only valid with 3_2_LFE coding mode.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • lfeFilter

      Eac3Settings.Builder lfeFilter(Eac3LfeFilter lfeFilter)
      Applies a 120Hz lowpass filter to the LFE channel prior to encoding. Only valid with 3_2_LFE coding mode.
      Parameters:
      lfeFilter - Applies a 120Hz lowpass filter to the LFE channel prior to encoding. Only valid with 3_2_LFE coding mode.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • loRoCenterMixLevel

      Eac3Settings.Builder loRoCenterMixLevel(Double loRoCenterMixLevel)
      Specify a value for the following Dolby Digital Plus setting: Left only/Right only center mix. MediaConvert uses this value for downmixing. How the service uses this value depends on the value that you choose for Stereo downmix. Valid values: 3.0, 1.5, 0.0, -1.5, -3.0, -4.5, -6.0, and -60. The value -60 mutes the channel. This setting applies only if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Left only/Right only center.
      Parameters:
      loRoCenterMixLevel - Specify a value for the following Dolby Digital Plus setting: Left only/Right only center mix. MediaConvert uses this value for downmixing. How the service uses this value depends on the value that you choose for Stereo downmix. Valid values: 3.0, 1.5, 0.0, -1.5, -3.0, -4.5, -6.0, and -60. The value -60 mutes the channel. This setting applies only if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Left only/Right only center.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
    • loRoSurroundMixLevel

      Eac3Settings.Builder loRoSurroundMixLevel(Double loRoSurroundMixLevel)
      Specify a value for the following Dolby Digital Plus setting: Left only/Right only. MediaConvert uses this value for downmixing. How the service uses this value depends on the value that you choose for Stereo downmix. Valid values: -1.5, -3.0, -4.5, -6.0, and -60. The value -60 mutes the channel. This setting applies only if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Left only/Right only surround.
      Parameters:
      loRoSurroundMixLevel - Specify a value for the following Dolby Digital Plus setting: Left only/Right only. MediaConvert uses this value for downmixing. How the service uses this value depends on the value that you choose for Stereo downmix. Valid values: -1.5, -3.0, -4.5, -6.0, and -60. The value -60 mutes the channel. This setting applies only if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Left only/Right only surround.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
    • ltRtCenterMixLevel

      Eac3Settings.Builder ltRtCenterMixLevel(Double ltRtCenterMixLevel)
      Specify a value for the following Dolby Digital Plus setting: Left total/Right total center mix. MediaConvert uses this value for downmixing. How the service uses this value depends on the value that you choose for Stereo downmix. Valid values: 3.0, 1.5, 0.0, -1.5, -3.0, -4.5, -6.0, and -60. The value -60 mutes the channel. This setting applies only if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Left total/Right total center.
      Parameters:
      ltRtCenterMixLevel - Specify a value for the following Dolby Digital Plus setting: Left total/Right total center mix. MediaConvert uses this value for downmixing. How the service uses this value depends on the value that you choose for Stereo downmix. Valid values: 3.0, 1.5, 0.0, -1.5, -3.0, -4.5, -6.0, and -60. The value -60 mutes the channel. This setting applies only if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Left total/Right total center.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
    • ltRtSurroundMixLevel

      Eac3Settings.Builder ltRtSurroundMixLevel(Double ltRtSurroundMixLevel)
      Specify a value for the following Dolby Digital Plus setting: Left total/Right total surround mix. MediaConvert uses this value for downmixing. How the service uses this value depends on the value that you choose for Stereo downmix. Valid values: -1.5, -3.0, -4.5, -6.0, and -60. The value -60 mutes the channel. This setting applies only if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Left total/Right total surround.
      Parameters:
      ltRtSurroundMixLevel - Specify a value for the following Dolby Digital Plus setting: Left total/Right total surround mix. MediaConvert uses this value for downmixing. How the service uses this value depends on the value that you choose for Stereo downmix. Valid values: -1.5, -3.0, -4.5, -6.0, and -60. The value -60 mutes the channel. This setting applies only if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Left total/Right total surround.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
    • metadataControl

      Eac3Settings.Builder metadataControl(String metadataControl)
      When set to FOLLOW_INPUT, encoder metadata will be sourced from the DD, DD+, or DolbyE decoder that supplied this audio data. If audio was not supplied from one of these streams, then the static metadata settings will be used.
      Parameters:
      metadataControl - When set to FOLLOW_INPUT, encoder metadata will be sourced from the DD, DD+, or DolbyE decoder that supplied this audio data. If audio was not supplied from one of these streams, then the static metadata settings will be used.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • metadataControl

      Eac3Settings.Builder metadataControl(Eac3MetadataControl metadataControl)
      When set to FOLLOW_INPUT, encoder metadata will be sourced from the DD, DD+, or DolbyE decoder that supplied this audio data. If audio was not supplied from one of these streams, then the static metadata settings will be used.
      Parameters:
      metadataControl - When set to FOLLOW_INPUT, encoder metadata will be sourced from the DD, DD+, or DolbyE decoder that supplied this audio data. If audio was not supplied from one of these streams, then the static metadata settings will be used.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • passthroughControl

      Eac3Settings.Builder passthroughControl(String passthroughControl)
      When set to WHEN_POSSIBLE, input DD+ audio will be passed through if it is present on the input. this detection is dynamic over the life of the transcode. Inputs that alternate between DD+ and non-DD+ content will have a consistent DD+ output as the system alternates between passthrough and encoding.
      Parameters:
      passthroughControl - When set to WHEN_POSSIBLE, input DD+ audio will be passed through if it is present on the input. this detection is dynamic over the life of the transcode. Inputs that alternate between DD+ and non-DD+ content will have a consistent DD+ output as the system alternates between passthrough and encoding.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • passthroughControl

      Eac3Settings.Builder passthroughControl(Eac3PassthroughControl passthroughControl)
      When set to WHEN_POSSIBLE, input DD+ audio will be passed through if it is present on the input. this detection is dynamic over the life of the transcode. Inputs that alternate between DD+ and non-DD+ content will have a consistent DD+ output as the system alternates between passthrough and encoding.
      Parameters:
      passthroughControl - When set to WHEN_POSSIBLE, input DD+ audio will be passed through if it is present on the input. this detection is dynamic over the life of the transcode. Inputs that alternate between DD+ and non-DD+ content will have a consistent DD+ output as the system alternates between passthrough and encoding.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • phaseControl

      Eac3Settings.Builder phaseControl(String phaseControl)
      Controls the amount of phase-shift applied to the surround channels. Only used for 3/2 coding mode.
      Parameters:
      phaseControl - Controls the amount of phase-shift applied to the surround channels. Only used for 3/2 coding mode.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • phaseControl

      Eac3Settings.Builder phaseControl(Eac3PhaseControl phaseControl)
      Controls the amount of phase-shift applied to the surround channels. Only used for 3/2 coding mode.
      Parameters:
      phaseControl - Controls the amount of phase-shift applied to the surround channels. Only used for 3/2 coding mode.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • sampleRate

      Eac3Settings.Builder sampleRate(Integer sampleRate)
      This value is always 48000. It represents the sample rate in Hz.
      Parameters:
      sampleRate - This value is always 48000. It represents the sample rate in Hz.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
    • stereoDownmix

      Eac3Settings.Builder stereoDownmix(String stereoDownmix)
      Choose how the service does stereo downmixing. This setting only applies if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Stereo downmix.
      Parameters:
      stereoDownmix - Choose how the service does stereo downmixing. This setting only applies if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Stereo downmix.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • stereoDownmix

      Eac3Settings.Builder stereoDownmix(Eac3StereoDownmix stereoDownmix)
      Choose how the service does stereo downmixing. This setting only applies if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Stereo downmix.
      Parameters:
      stereoDownmix - Choose how the service does stereo downmixing. This setting only applies if you keep the default value of 3/2 - L, R, C, Ls, Rs for the setting Coding mode. If you choose a different value for Coding mode, the service ignores Stereo downmix.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • surroundExMode

      Eac3Settings.Builder surroundExMode(String surroundExMode)
      When encoding 3/2 audio, sets whether an extra center back surround channel is matrix encoded into the left and right surround channels.
      Parameters:
      surroundExMode - When encoding 3/2 audio, sets whether an extra center back surround channel is matrix encoded into the left and right surround channels.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • surroundExMode

      Eac3Settings.Builder surroundExMode(Eac3SurroundExMode surroundExMode)
      When encoding 3/2 audio, sets whether an extra center back surround channel is matrix encoded into the left and right surround channels.
      Parameters:
      surroundExMode - When encoding 3/2 audio, sets whether an extra center back surround channel is matrix encoded into the left and right surround channels.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • surroundMode

      Eac3Settings.Builder surroundMode(String surroundMode)
      When encoding 2/0 audio, sets whether Dolby Surround is matrix encoded into the two channels.
      Parameters:
      surroundMode - When encoding 2/0 audio, sets whether Dolby Surround is matrix encoded into the two channels.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • surroundMode

      Eac3Settings.Builder surroundMode(Eac3SurroundMode surroundMode)
      When encoding 2/0 audio, sets whether Dolby Surround is matrix encoded into the two channels.
      Parameters:
      surroundMode - When encoding 2/0 audio, sets whether Dolby Surround is matrix encoded into the two channels.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also: